Ductwork & Ventilation Installation (Duct Contractor)
Also called: duct contractor, HVAC ductwork, duct installation, ventilation ducting, fire damper installation
NLS Contractors installs ductwork and ventilation in Riyadh, Jeddah, Dammam and Khobar: galvanised and pre-insulated duct, fire and smoke dampers, grilles and diffusers, AHUs, fans, kitchen and toilet extract, and stair pressurisation fans. Work follows SMACNA, NFPA 90A and SBC 501, with leakage and damper tests recorded for handover.
Ductwork is the part of an air conditioning system that people notice only when it whistles, leaks or will not balance. It carries conditioned air from the air handling unit to the room and used air back, and its quality shows in noise and in how much of the fan's air arrives where it should.
Ducts are galvanised sheet steel or pre-insulated panel, built to the SMACNA construction class in the specification, which sets sheet gauge, joint type and reinforcement by pressure class. Pre-insulated duct goes up quickly and carries its insulation with it. Galvanised duct is insulated and clad after leak testing. Flexible connections, volume control dampers and access doors are placed per the drawings.
Insulation and routing matter in a hot climate. Duct running through a roof void or across a plant deck gains heat before the air reaches the room, so insulation thickness and cladding follow the specification, and the vapour barrier is sealed at every joint and hanger to stop condensation on the outside surface.
Fire and smoke dampers sit where ducts cross fire-rated walls and floors, follow NFPA 90A, and need their own access panels so they can be tested and reset. Where smoke control is specified, NFPA 92 applies, and that covers stair pressurisation and the fans that run it. Kitchen and toilet extract ducts carry their own requirements for material, fall and access, as the specification states.
Leakage testing proves the duct to the specified class before it is insulated or hidden above a ceiling. Dampers are function tested, and smoke control systems are tested to their specification. A ceiling closed over untested duct is the expensive way to find a leak. Sealing at joints, hangers and penetrations is checked on site.
AHUs, fans and dampers can be client-supplied or sourced through NLS Power, and installed and connected under the same offer. Price depends on duct area or weight, insulation, the number of dampers and terminals, and ceiling access. Lead time depends on scope and the offer states it. Send the duct layout drawings, equipment schedules, the specification, the BOQ and the site city.
Specifications
- ✓Duct: galvanised or pre-insulated, built to SMACNA construction classes
- ✓Components: fire and smoke dampers, grilles and diffusers, volume dampers, access panels
- ✓Equipment: AHUs, supply and extract fans, kitchen and toilet extract, stair pressurisation fans
- ✓Standards: SMACNA, NFPA 90A, NFPA 92 where smoke control is specified, SBC 501
- ✓Tests: duct leakage test, damper function tests
- ✓Handover: shop drawings, leakage test records, damper test records, as-builts
Frequently Asked Questions
What leakage test applies to ductwork?+
The one the specification names: duct class, test pressure and the allowable leakage rate. Sections are tested before insulation, and the signed records go to the consultant.
Where are fire dampers required?+
Where ducts cross fire-rated walls and floors, as the drawings and NFPA 90A show. Each damper needs an access panel so it can be tested and reset.
Do you install stair pressurisation fans?+
Yes. The fans, ducts, dampers and their wiring are installed, and the system is tested to the smoke control specification. Testing usually involves the fire alarm and the BMS, so those packages are coordinated.
Is pre-insulated duct better than galvanised duct?+
Neither is better in general. Pre-insulated duct installs fast and is common indoors. Galvanised duct with site insulation suits some pressure classes and exposed runs. The specification decides.
Is NLS Contractors a duct contractor in Saudi Arabia?+
NLS Contractors takes ductwork and ventilation as a works package: galvanised and pre-insulated duct, dampers, grilles and diffusers, fans and AHUs, to SMACNA, NFPA 90A and SBC 501. It is priced from the duct drawings and BOQ and built from specialist installer and supplier quotes, with leakage and damper tests recorded for handover.
Who supplies Ductwork & Ventilation Installation (Duct Contractor) in Saudi Arabia?+
NLS Contractors (Northlane Solutions Company) supplies Ductwork & Ventilation Installation (Duct Contractor) across Saudi Arabia, including Riyadh, Jeddah, Dammam and Jubail. Send your specification and quantities to info@nlscontractors.com or info@northlanesolution.com for a quotation.
Related products

Sprinkler, Hydrant & Fire Pump Installation
NLS Contractors installs sprinkler, hydrant and fire pump systems in Riyadh, Jeddah, Dammam and Khobar and across the Kingdom: sprinkler grids, risers and standpipes, hydrants, hose cabinets and pump sets with fire water tank connections. Work follows NFPA 13, 14, 20 and 24 and SBC 801, with Civil Defense acceptance support and test certificates at handover.

Testing, Adjusting & Balancing (TAB) and HVAC Commissioning
NLS Contractors delivers testing, adjusting and balancing (TAB) and HVAC commissioning as a works package in Riyadh, Jeddah, Dammam and Khobar: airflow and water flow measurement, balancing to design values and functional testing, using NEBB or AABC procedures as specified and ASHRAE Guideline 0. Handover includes TAB reports, balancing sheets, functional test records and a commissioning report.

Split, VRF & Packaged AC Installation
NLS Contractors installs split, VRF and packaged air conditioning in Riyadh, Jeddah, Dammam and Khobar and across the Kingdom. Scope covers indoor and outdoor units, refrigerant piping tested under pressure and vacuum, condensate drains, control wiring and power connection, to SBC 501 and SBC 601. Handover includes piping layouts, test records, commissioning sheets and as-builts.

Chilled Water Piping & Plant Rooms
NLS Contractors installs chilled water piping and plant rooms in Riyadh, Jeddah, Dammam and Khobar: chillers, pumps, heat exchangers and cooling towers where used, with carbon steel or HDPE pipework, valves, insulation and vibration isolation. Piping follows ASME B31.9 and SBC 501. Handover includes isometrics, test records, flushing certificates and as-builts.