Sanitary Fixtures & Fittings Installation
NLS Contractors installs sanitary fixtures and fittings in Riyadh, Jeddah, Dammam and Khobar and across the Kingdom: WCs, basins, urinals, showers, taps, bidet sprays, ablution points and accessible fixtures, supplied by the client or procured to the schedule. Mounting heights, supports and sealing are checked room by room, with accessible fixtures to SBC 201.
Fixtures are the visible end of the plumbing package, and the part the owner inspects first. Every WC, basin, shower and tap is judged on how level it sits, whether it leaks and whether it works when the room is handed over. Installation is therefore done room by room against a checklist, not as one bulk operation.
The scope covers WCs, floor-standing or wall-hung on carriers, basins, urinals, showers, taps and mixers, bidet sprays and ablution points, and the fittings that go with them: traps, angle valves, flexible connectors and fixing sets. In Saudi buildings bidet sprays and ablution points are standard items, and the schedule lists them by room.
Fixtures can be supplied by the client to the schedule, or procured and priced in the offer. Where the specification asks for water-efficient fixtures, the offer states the model and flow rating. Samples are approved before bulk ordering, since a changed model can mean different rough-in dimensions behind the wall.
Accessible fixtures are set out per SBC 201 (architectural): accessible WC cubicles, grab rails, basins, mounting heights and clearances around each fixture. Wall-hung WCs and urinals need carriers and reinforced walls built in before tiling, so plumbing and wall finishes are coordinated early.
Toilet blocks in offices, schools and camps repeat the same room many times, so a first room is installed as a mock-up and approved before the rest follow. Mounting heights, spacing between fixtures and the clear space in front of each are checked there, and the approved room becomes the reference for snag inspection.
Finishing includes silicone sealing at wall and floor joints, leak checks under working pressure, adjustment of flush volumes and tap flow, and removal of protective film. A snag list is closed room by room. Price depends on the number and type of fixtures, whether they are supplied, and access. Lead time depends on scope and the offer states it. Send the fixture schedule, the plumbing drawings, the room list, the specification and the site city.
Specifications
- ✓Fixtures: WCs, basins, urinals, showers, taps, bidet sprays, ablution points
- ✓Accessible fixtures and clearances per SBC 201 (architectural)
- ✓Supply: client-supplied or procured to the fixture schedule
- ✓Water-efficient fixtures where the specification asks
- ✓Installation: mounting heights, carriers and supports, silicone sealing, leak checks
- ✓Handover: fixture schedule, installation checklist per room, snag close-out
Frequently Asked Questions
Can you install fixtures that the client has already bought?+
Yes. Delivered items are checked against the schedule on receipt and damage is recorded before installation. Installation, carriers, sealing and leak checks sit inside the plumbing scope.
Which fixtures fall under the accessibility requirements?+
Accessible WCs, basins and showers, together with their grab rails, mounting heights and clearances, are set out per SBC 201. The drawings and the schedule show which rooms carry them.
How are leaks checked after fixtures are installed?+
Each fixture is run under working pressure, and the joints, traps and connections are inspected. The result is recorded per room on the installation checklist.
When in the construction sequence are fixtures installed?+
After wall and floor finishes, so tiles are not damaged. Carriers and supports go in much earlier, before the walls are closed, and the sequence is agreed with the finishing package.
Who supplies Sanitary Fixtures & Fittings Installation in Saudi Arabia?+
NLS Contractors (Northlane Solutions Company) supplies Sanitary Fixtures & Fittings Installation across Saudi Arabia, including Riyadh, Jeddah, Dammam and Jubail. Send your specification and quantities to info@nlscontractors.com or info@northlanesolution.com for a quotation.
Related products

Water Tanks & Booster Pump Sets
NLS Contractors installs water storage tanks and booster pump sets in Riyadh, Jeddah, Dammam and Khobar and across the Kingdom: GRP, concrete or steel tanks, transfer pumps, VFD booster sets in duty and standby, level controls and chlorination points. Work follows SBC 701 and the pump maker's requirements, with disinfection and pump test records at handover.

Rainwater & Roof Drainage
NLS Contractors installs rainwater and roof drainage in Riyadh, Jeddah, Dammam and Khobar and across the Kingdom: roof drains, downpipes, gutters, overflow outlets and the connection to the storm network. Sizing follows the rainfall intensity the consultant sets, under SBC 701. Handover includes roof drainage layouts, water test records and as-builts.

Cold & Hot Water Supply Piping
NLS Contractors installs cold and hot water supply piping in Riyadh, Jeddah, Dammam and Khobar and across the Kingdom: risers, branches, valves, insulation and water heaters, in PPR to ISO 15874, copper, stainless steel or HDPE to ISO 4427. Work follows SBC 701, with pressure tests, flushing and disinfection certificates in the handover.

Sanitary Drainage & Sewerage Piping
NLS Contractors installs sanitary drainage and sewerage piping in Riyadh, Jeddah, Dammam and Khobar and across the Kingdom: soil, waste and vent stacks in uPVC or HDPE, floor drains, cleanouts, manholes and the connection to the public sewer. Work follows SBC 701 and National Water Company requirements, with test records, invert levels and as-builts at handover.