Energy Metering & Monitoring Systems
Energy metering and monitoring installs electrical multi-function meters, water meters and chilled water BTU meters, with a metering network to the BMS or an energy dashboard. Meters follow IEC 62053 accuracy classes and Modbus or BACnet, with SBC 601 in view, in Riyadh, Jeddah, Dammam and Khobar. Handover includes the metering schedule, single line diagram and test certificates.
A building that cannot see where its energy goes cannot cut it, bill it fairly or prove it met the energy conservation requirements. Energy metering fixes that by measuring electricity, water and chilled water at the points that matter and sending the readings to a place where someone can use them. NLS Contractors takes it as a works package: meters installed and wired, the metering network, the integration to the BMS or an energy dashboard, and the testing and handover records.
Three meter types make up most packages. Electrical multi-function meters read voltage, current, power, energy and power factor on incomers, feeders and tenant circuits. Water meters read potable, irrigation and cooling tower make-up lines. Chilled water energy meters, usually called BTU meters, combine a flow sensor with supply and return temperature sensors to give the cooling energy delivered to a floor, a tenant or an air handler.
Meter accuracy is set by class. IEC 62053 defines accuracy classes for electricity meters, and the specification names the class for each location. Communication is normally Modbus RTU or Modbus TCP, or BACnet, so the readings come into the BMS without a separate reading system. SBC 601 covers energy conservation requirements for the building, and the metering schedule is where the design proves it can measure what that code asks it to.
Sub-metering is the useful part. Metering by tenant supports billing, metering by floor shows where a building is out of balance, and metering by plant item shows the chillers, pumps and lifts that draw the most. Peak demand alarms warn the operator before a limit is crossed, and monthly consumption reports go to whoever manages the building.
Deliverables are the metering schedule, the metering single line diagram, meter test certificates, dashboard configuration and operator training. Electrical metering and distribution equipment can be sourced through NLS Power (nlspower.com) and priced in the same offer, or installed as client-supplied.
To price metering in Riyadh, Jeddah, Dammam or Khobar, send the metering schedule or single line diagram, the BOQ, the meter specification clause and whether the readings go to the BMS or a separate dashboard. Price and lead time depend on the meter count and the network, and the offer states both.
Specifications
- ✓Meters: electrical multi-function, water, and chilled water energy (BTU) meters
- ✓Accuracy classes per IEC 62053; Modbus or BACnet communications to the BMS or an energy dashboard
- ✓Energy conservation requirements of SBC 601 considered in the metering schedule
- ✓Sub-metering by tenant, floor and plant item, with peak demand alarms and monthly consumption reports
- ✓Handover: metering schedule, metering single line diagram, meter test certificates, dashboard configuration, training
Frequently Asked Questions
What is a BTU meter?+
A chilled water energy meter. A flow sensor and two temperature sensors on the supply and return pipes calculate the cooling energy delivered, which is used to bill tenants or to check chiller plant performance.
Do meter readings need a separate system?+
Not usually. Meters with Modbus or BACnet outputs report into the BMS. A separate energy dashboard is added where the specification or the owner asks for billing-grade reports.
Can you install meters we have already bought?+
Yes. Installation, wiring, network setup and testing can be priced on client-supplied meters. The offer lists the meter models and communication protocol it assumes.
Who supplies Energy Metering & Monitoring Systems in Saudi Arabia?+
NLS Contractors (Northlane Solutions Company) supplies Energy Metering & Monitoring Systems across Saudi Arabia, including Riyadh, Jeddah, Dammam and Jubail. Send your specification and quantities to info@nlscontractors.com or info@northlanesolution.com for a quotation.
Related products

BMS Testing, Commissioning & Handover
BMS testing and commissioning covers point-to-point and loop checks, functional tests of every sequence, alarm tests and graphics verification, witnessed by the consultant. Stage gates run from pre-functional checks to site acceptance and punch list close-out in Riyadh, Jeddah, Dammam and Khobar, ending with signed record sheets, controller backups, as-builts and O&M manuals.

BMS Installation Works
BMS installation works cover field sensors and actuators, DDC panels, the controller network, the supervisory server and workstation, plus cabling and containment, priced from the point list. Built to ISO 16484 and BACnet (ASHRAE 135) in Riyadh, Jeddah, Dammam and Khobar, with shop drawings, I/O schedules, test records, controller backups and O&M manuals at handover.

DDC Controls for HVAC Systems
DDC controls for HVAC cover the panels, wiring, sensors, actuators, programming and graphics that run chillers, AHUs, FCUs, VAV boxes, pumps, dampers and valves. Work follows the consultant's sequences of operation, with ASHRAE Guideline 36 where specified, in Riyadh, Jeddah, Dammam and Khobar. Handover includes control schematics, I/O lists, functional test records and trend logs.

BMS for Hospitals & Healthcare Campuses
BMS for hospitals and healthcare campuses covers central plant and the AHUs serving theatres, wards and isolation rooms, with room pressure, temperature and humidity monitoring. Built to ISO 16484 with ASHRAE 170 and NFPA 99 monitoring points across Riyadh, Jeddah and the Eastern Province, with building-by-building handover, alarm schedules, trend logs and test records.

BMS Integration: BACnet, Modbus & Graphics
BMS integration reads chillers, VFDs, energy meters, generators, UPS, lighting controls and the fire alarm panel (monitoring only) into one supervisory layer over BACnet/IP, BACnet MS/TP and Modbus. Scope covers gateways, network design, graphics and alarm routing in Riyadh, Jeddah, Dammam and Khobar, with an integration matrix and point mapping tables at handover.